Polarity will change every 3 hours. Learn more. Select Options. Please consider. If the cell is old, just get the PLC1400 kit. Jandy makes the Purelink Power Center that combines the Aqualink and Aquapure controls in one cabinet. Many of these units have been shipped with bad circuit boards, as my pool professional was told by the Jandy tech. This is not a DIY product. Refer to Maintenance Procedure for acid wash cleaning. This difference in readings started about 1 week ago. Ensure that the flow/temp/salinity sensor is installed according to Section 3, Figure 11 of the owner's manual. Most common is the center pin.[9]. If you have a No-Flow error try resetting the circuit breaker and re-calibrating the tri-sensor before you consider replacing it. The only difference is the new part has a ground wire that was attached to the common ground.[15]. Reviewed in the United States on September 23, 2016, Reviewed in the United States on February 1, 2015, Reviewed in the United States on April 28, 2014. Ordered one off Amazon and got it replaced todaywith the help of the hubby. Drop in the Best When You Replace the Rest. Here is a test you can do to diagnose the trisensor. A common reason for the cell failing and getting error codes 120, 121 or 123 is one or more of the pins corroding and separating from its plate. ORP / External Control Interface 2. Had to down load from another site. $200 later guy said unit was shipped without a translatetor card???? Add To Cart. Balance the water to recommended levels in Section 4.5 of the owner's manual. Find inspiration for your home and garden. Very happy with this controller. Turn on pump. Can this be used to replace an old Aquapure 1400 control box? You use the% generation control to adjust the actual amount of chlorine generated to meet your pools chlorine need. Avoid using salt with anti-caking agents (sodium ferrocyanide, also known as YPS or yellow prussiate of soda) that could cause some discoloration of fittings and surface finishes in pool. What type of salt needs to be used for salt water chlorination? Cell trisensor senses temperature, salinity and flow. You need the Aquapure system with the control box and cell. Recheck. You know what? With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. These control pool and spa combinations sharing one set of equipment (Actuators included). You can recalibrate the unit if you are really sure about the actual salinity and you want the box to match your readings. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115 / 230 VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. 3 gpl is 3,000 ppm. JavaScript is disabled. Or just the control box? They are built of a rugged glass-filled polypropelene material, have standard Jandy unions, and are NSF listed for your commercial application. For example, at 50%, the cell will run for 15 minutes and off for 15 minutes. Haha! Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. We are sorry. Is it true that salt water chlorination is maintenance free? Follow cleaning procedures. The Salinity button C on the sanitizer user interface keypad can be used to determine salinity. Available in 7 or 14-blade configurations. Page 17 in the Jandy Power Center Installation Manual shows the location of the jumper. Red goes to green and blue goes to black/white. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. The cell cannot be repaired even though the plates may have life left in them. Thanks, Problem solved. See also, Section 6.4, Flow/Temp/Salinity Sensor Cleaning, Step 4 of the owner's manual. Please try again later. There were instructions included, but they were not as comprehensive as you would really need. 2) Order your Power Center. Use a salt that is at least 99.8% pure NaCl. The PureLink Power Centers combine all the features of the AquaLink Power Centers and AquaPure water purification electronics in one box. See Section 5, Operating Instructions section of the owner's manual. You can sometimes fix it by cleaning off the corrosion.[10]. I bought one of these units from another vendor three years ago. JavaScript is disabled. Many of these units have been shipped with bad circuit boards, as my pool professional was told by the Jandy tech. Need to, Your zip code will help us to provide you with the most up-to-date delivery information. Earn at least $9 in pool perks for this item by joining Pool Perks. It should read 75 F or 24 C. Next, press and hold the board H-Temp test button, and at the same time press the Salinity key (C) together with the Chlorine Production Rate arrow down key (A) on the front cover of the unit. More Details. We promise to never spam you, and just use your email address to identify you as a valid customer. Sorry, we were unable to perform your search at this time. The control center is connected with the pool circulation pump electrical source so that the electrolytic cell can only operate when the pool pump is on. See pages 13-14 in Jandy AquaPure Troubleshooting. It is ok to startup the chlorinator when there is a little bromide in the pool. Plug flow/temp/salinity sensor into connector on power center printed circuit board. I couldn't get one of the screws on the power panel off, Help Support TFP Trouble Free Pool is run by a dedicated group of volunteers that Read more, Hello , This is an inactive thread. Had to call a pool guy. The AquaPure does not have a flow switch, it has a flow sensor, which is a heated probe and and unheated probe and it works on the same principle as "wind chill".[1]. Regular Price: $212.61. The Power Center comes configured for the 1400 cell and the JL1 jumper must be cut if using the 700 cell. 2 - Screws, Power Interface. Remove and clean flow/temp/salinity sensor contacts. Even the High Voltage side wires were color coded identically. This action maintains the cell. However, when I power on the AquaLink PDA, it shows the water temp is 120 degrees. Jandy no longer supports parts for their older systems. (567 gm/24 Hr.). Car & Truck Safety & Security Accessories, DEWALT DCCS620B 20V MAX Cordless Li-Ion 12 in. Tri-Sensor R-kits will ship first, beginning with date code 10/6/14. We selected and analyzed the cases involving AEDs. ), PURE1400 - 1.25 lb./24 Hr. Brush down the affected walls and follow the directions in Section 5.4.1 of the owner's manual, Shocking. | IQ20-A. The remaining bromide in the pool will produce a white emulsion (chemical reaction). 624537. Find a Dealer AquaPure Downloads Document ID SL5801CE No warranty when purchased online. Remove cell for inspection. * Pricing, promotions and availability may vary by location and at lesliespool.com. Wood Concrete Projects Built Projects Selected Projects Cultural Architecture Cultural Center Yuri Vital Iceberg Sao Paulo So Paulo Brazil Published on December 27, 2020 Cite: "Porto Seguro . Shop Online or at any of our 900+ retail stores! See Section 5, Operating Instructions of the owner's manual. While the salt water chlorinator prevents the user from needing to add chlorine to the pool on a regular basis, some maintenance, in regards to water balancing, will still need to be accomplished. Do Not Sell or Share My Personal Information. The remaining bromide will not harm the users, pool equipment or the pool. Add To Cart. Recommend strongly. Zodiac R0467600 Printed Circuit Board Power Interface Replacement for Select Zodiac Jandy Pool and Spa Power Centers. Pool or Spa Only Controls are for use with single body pool or spa utilizing one set of equipment. On the other hand if the readings are different then it indicates that there is a problem with the board. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. The AquaPure has a 3 hour polarity cycle time (3 hours one polarity, 3 hours reverse polarity). It is being practiced by thousands of pool owners just like you. The Flow & Salinity Sensor is Jandy P/N R0452500. In preparation, I had upgraded our controller to the latest release of hardware and software, so I was familiar with most of the circuitry involved. We paired it with the APUREM. There was a problem completing your request. It may not display this or other websites correctly. Below 51F (11C), chlorine production is not permitted; operating the chlorinator in cold water might result in over-chlorinated pool water. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. We could have gotten by with the PLC700 but this We made the decision to go to a salt water pool system. However, if you have any doubts, do not try this!!! The audible alarm is described on page 34 of the Jandy Pro Series AquaPure/PureLink Power Center and Cell Kit | Installation and Operation Manual.[4]. Dont use the little adaptor card between the cord plug and the circuit board. You can remove your cell for winter and install the dummy cell. Broadcast or spread the salt into the outer perimeter of the pool, or into the shallow end of the pool for quick and even distribution. You can check the calibration by doing the following below procedure. To avoid clogging the filter or damaging the control center and pump, do not add salt through the skimmer, main drain, or surge tank. The PLC700's have a 2 prong plug system and the PLC1400's have a 3 prong plug system. Andy tech support makes jokes that I should get it fixed before my pool turns green and yet have not been able to fix the problems nor willing to try. (283 gm/24 Hr. The three pins go inside and connect to the plates. Please select a nearby store with available inventory to process your order. There are numerous sites that have detailed information about the install. Then the Aquapure system will be connected to your Aqualink system. cargsl; Jul 19, 2022; Salt Water Chlorine Generators (SWG) Replies 10 Rely on its sturdy design and simple features to create your saltwater oasis. Am I correct in assuming that the box contains the internal components such as the control, A: Turn power to unit off and back on (Cycle Power). The mineral purifier cartridge may have ruptured. Find a Dealer AquaPure Salt Water Pool System Downloads Document ID SL6605 Installation by a qualified pool professional required. Recieved and installed myself. Compact Chainsaw (Tool Only) New, JBL Live 300TWS True Wireless Earbuds Sweat and Water Resistent, Lenovo IdeaPad 3 14" FHD Laptop Intel Core i7-1165G7 8GB RAM 512GB SSD, Lenovo ThinkPad X1 Carbon Gen 9 Intel Laptop, 14.0" IPS Low Blue Light, vPro, ONE PIECE TCG BOOSTER BOX ENGLISH Paramount War FACTORY SEALED NEW, Dyson V10 Animal + Cordless Vacuum Cleaner | Purple | Certified Refurbished, Legion 5 Pro 16" Gaming Laptop QHD 165Hz R9-6900HX 16GB RAM 1TB SSD RTX 3070 Ti, Men Cap Army Hat Cadet Castro Military Patrol Baseball Summer Camo Camouflage, adidas AEROREADY Designed to Move Feelready Sport Tee Men's, DJI Mavic Mini Intelligent Flight Battery-DJI Certified Refurbished, Sun Visor Hat Golf Tennis Beach Men Baseball Cap Adjustable Summer Plain Women, Intel Core i9-13900KF Unlocked Desktop Processor - 24 Cores (8P+16E) & 32 Thread, NEW WR60X10141 REFRIGERATOR FREEZER EVAPORATOR FAN MOTOR FITS GE HOTPOINT, PlayStation 5 Digital Edition God of War Ragnarok Bundle, Pokemon Dragonite VSTAR Deck Holder Tin Collection Factory Sealed Case (6 Units), Micron PRO 7450 PRO 15.36 TB Solid State Drive - 2.5" Internal - U.3 [PCI, Intel Core i5-12600K Unlocked Desktop Processor - 10 Cores (6P+4E) And 16 Thread, SanDisk 1TB Extreme Portable SSD V2 1050 MB/s USB-C USB 3.2 Gen 2 Solid State, AZZARO pour Homme Cologne 3.3 oz / 3.4 oz Tester (Rechargeable-Refillable), 6.5 x 9.25 Padded Bubble Mailer Color Logo, US Gold $20 Liberty Head Double Eagle - NGC MS62 - Random Date, Crocs Men's and Women's LiteRide Clogs | Slip On Shoes, Apple iPhone 11 Pro 64GB Unlocked Smartphone - Very Good, 6 x 8 Paperboard Mailjacket Envelope (No padding), Apple iPhone 12 Pro Max A2342 128GB Unlocked Good Condition, Scarlet and Violet Base Set Booster Box Pokemon TCG SEALED PREORDER SHIPS 3/31. Pricing and offers are subject to change. You can buy this product once, or subscribe to have this product delivered to you as frequently as you wish. Will salt from the salt water chlorinator deteriorate the metal components in my pool? In addition, the AquaPure threads are proprietary and Jandy does not offer replacement proprietary unions (the "male" piece). Salt should be added to the pool when necessary. Be the first to review this product! good documentation. Report PoolGate Gold Supporter TFP Guide Jun 7, 2017 7,748 Damascus, MD Pool Size 29000 Sorry - Air temperature sensor. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. A letter will be included with each new Tri-Sensor ALERTING Installers about the new installation instructions. Disconnect the flow salinity temp sensor from the board. See Section 5.4 of the owner's manual, Startup. It is possible his sensors are reversed. Jandy / Zodiac PLC1400 Replacement Cell Kit for AquaPure / PureLink 1400. While the salt shouldn't have any effect on the person if a small amount is swallowed, please keep in mind that the water is chlorinated and chlorine should not be consumed. The LCD should read 2.8 gpl*. Unit came with panel knocked out and the circuit board was bad. No instructions contained w/unit. Low salt concentration below 2.0 gpl will cause premature cell failure. VERY GOOD PRODUCT, indeed, easy to install. The AquaPure salt-water chlorine sanitizing systems uses salt water to deliver water sanitation by generating chlorine. Adjust total alkalinity to 80-120ppm. This could be a defective automatic timer or pump switch or loose connection at the automatic timer or pump switch. The PureLink DC Cord is Jandy P/N R0402800. A separate communication will follow . That is NOT what you have. If the Aquapure is disconnected from the Aqualink, then you should be able to set chlorine production from the front panel on the Aquapure. It appears that Aqualink stops talking to Aquapure when the Aqualink water temperature sensor is inoperative.[12]. There are beads at the bottom of my pool, what does it mean? Reviewed in the United States on April 8, 2017. Determine the amount of salt necessary to add from an appropriate chart. The LCD display on the user interface offers monitoring of chlorine production, cell modes, salinity level, temperature, water flow and diagnostics. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115/230VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. AquaPure Electronic Salt Water Chlorinator & PureLink Water Purification System Power Center & Cell Kit Installation & Operation Manual, AquaPure and PureLink Tri-Sensor Replacement Kits. The Jandy AquaPure APUREM salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. See Sections 6.4 of the owner's manual. An optional "Spool" Piece (sold separately) used to be available to replace the cell during winterizing or cell maintenance. The AquaPure system offers two cells that can generate different maximum amounts of chlorine in a 24 hour period. This difference in readings started about 1 week ago. See Section 6.5 of the owner's manual, Winterizing. Aqualink prevents the Aquapure system from proper operation without a functioning water temperature signal from the Aqualink stand alone water temperature sensor, regardless of what the SWG flow sensor says. I've had a Jandy Aquapure 1400 since I opened the pool 4 years ago, and it's in the process of dying. This may be necessary after heavy rains, backwashing and refilling, excessive splash out, etc. While still holding the two front board test buttons press the Pool Temperature key (D). In the case of a salt water chlorinator, the salt may damage the stone along the water line over time (crystallization). The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Quantity. Works like a champ. Set Boost mode and allow to run for 24 hours. When a FREEZE CONTROLLER is used on pump equipment and the chlorinator is run through the winter, turn the CHLORINE PRODUCTION down to 10 - 20%. We are a registered 501(c)3 non-profit that is funded by user donations. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. inground with iAqualink remote control. Less work = longer life. The sensor connects to the same spot. This piece has been discontinued and is no longer available. Scale formation on pool equipment. Drop in the Best When You Replace the Rest. This page was last edited on 21 November 2022, at 19:29. You need to determine the correct Revisio, Q: Reviewed in the United States on June 20, 2014. Please try again. It displays the salt level in PPM on the display, and you can set the production rate (0-100%) on the LCD display, or you can integrate the system with a Jandy controller as I did. Test the salt level with a K-1766 Taylor Salt Test. Polarity Inversion is what salt water chlorinators use to periodically remove scale from the electrode plates. However, when I power on the AquaLink PDA, it shows the water temp is 120 degrees. Jandy APUREM AquaPure Salt Generator Power Center, Brand new returned unit - Never installed just opened, Create a Saltwater Oasis in Your Backyard, Automatic self-cleaning feature ensures consistent operation and extended lifespan of the cell, Exclusive Tri-Sensor technology provides reliable electronic water flow detection to sustain maximum performance, even at very low flow rates, Digital salinity read-out for accurate salt-level indication, Flow, temperature and status readings provide instant feedback on the current operation, When combined with PureLink power centers, AquaLink and AquaPure work together for the ultimate in pool sanitizing and remote operation convenience, Seamless communication with AquaLink Control systems enables easy monitoring of salt levels and convenient, precise sanitizer output settings, Note: The salt cells are sold separately Reviewed in the United States on October 9, 2013. Check for correct operation of the pump. I would say your pool temp sensor has gone bad. The Jandy AquaPure system consists of a AquaPure Power Center or PureLink Power Centers and either a PURE700 cell or a PURE1400 cell. I bought one of these units from another vendor three years ago. A member found that the new part fit perfectly with the same mounting holes. Remove obstruction and/or clean cell. The Jandy AquaPure salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. Andy tech support makes jokes that I should get it fixed before my pool turns green and yet have not been able to fix the problems nor willing to try. Had to replace our original, 14 year old system which developed a front board issue. Error posting question. Adjust CHLORINE PRODUCTION to desired percentage. Jandy Pro Series AquaPure Power Pack AquaPure Salt Chlorinator Models Sanitizer Type Body Material Chlorine Connections Input Current Output Pool Size Recommended Flow Rate Maximum Pressure Recommended Tablets Chamber Capacity of Chlorine AquaPure Power Pack and PureLink Cell Kit, 7 Blade #PLC700 Saltwater Chlorinator PPGF See Section 6 of the owner's manual, User Maintenance Instructions. (Cycle Power). Manually shock the pool following the directions in Section 5.4.1 of the owner's manual, Shocking. The problem is that the O-rings can leak, which creates a corrosive mix of water, salt, hydrogen gas and chlorine gas. Air, pool water, and SWG pool water. We are a registered 501(c)3 non-profit that is funded by user donations. It is the box in which the bezel, printed circuit board, service control panel and relays of the system control are installed and to which the pool equipment is connected. Many AquaPure display problems seem to get fixed by powering the Power Center and Aqualink panel if connected off at the circuit breakers, waiting a few minutes, and powering everything back on.[13]. View More Details. Rely on its sturdy design and simple features to create your saltwater oasis. Product information Feedback Would you like to tell us about a lower price? Stainless steel is better adapted to resist salt than Galvanised steel. You will get much more visibility by. Please note: This item is only available for in-store pickup and the selected store is out of stock. >PoolAndSpaPartsDepot.com is Open for Business! Look at the label on the CPU for the firmware revision. Dilute pool with fresh water. Add salt as described in Section 4.7 of the owner's manual. See Section 4.5 of the owner's manual. Press and hold the test buttons marked salinity and R-temp. A member had the problem of his Aquapure resetting to 35% every time it was powered on by the timer. No, a pool treated by salt water chlorination is a chlorinated pool in which the chlorine is produced automatically. Feel free to leave us a message and we will be in touch as soon as an agent is available. That picture was after Snowmageddon. Ensure there is no loss of pump prime or clogged strainer baskets. FREE delivery Feb 16 . Reviewed in the United States on December 6, 2014. Zodiac / Jandy R0476400 Replacement Sensor Kit for AquaPure PLC700 / PLC1400. This AquaPure foundation power center pack is designed to se with Zodiac Jandy AquaPure PureLink cell kit. 1 - Face Plate, Control Center, APUREM. Get 1 point for every $1 spent. 3.9 out of 5 stars 35. They are sold as a kit.[2]. I chose the Zodiac PLC1400 to pair with it. Thanks for identifying the water temperature sensor that will also have to be replaced. 99. Otherwise the back circuit board may need replacement. One method is an additional PVC union after each end of the cell. Includes: 1 - Power Interface Board Assembly. 3.0 to 3.5 gpl of salt is recommended for optimum water conditions. $195.99. Will there be any harm if someone swallows salt water in a salt chlorinated pool? To be more specific, do you mean the control board for the salt cell? The Jandy AquaPure APUREM salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. The purer the salt, the better the life and performance of the electrolytic cell. After installing began to flash code of 181 & 172. Please try again. From the Jandy controller, you can see the salt PPM, and you get a menu for setting the production rate percent for pool and spa modes - perfect. The prongs are sealed by O-rings and a compression plate held down by two screws. Is it true that a salt water chlorinator provides chlorine-free water? Remove and clean flow/temp/salinity sensor and reinstall. Apple is not a participant or sponsor of this promotion. Currently, Jandy has part R0481400 which is the round transformer. We had to replace our old aquapure system which was 15 years old. We evaluated 6535 medical consults of intoxication cases involving prescription and over-the-counter drugs in 2001. It's cheaper to go with another salt Unit came with panel knocked out and the circuit board was bad. ORP / External Control Interface 2. The basic Jandy Aqualink RS System involves FIVE key elements: 1) Order your System Level. Is this and the aquapure plc 1400 saltwater cell kit compatible with the iaqualink 2.0 bo, A: Check power. See Section 6.3 of the owner's manual Electrolytic Cell Cleaning. For a better experience, please enable JavaScript in your browser before proceeding. The center prong is the most common point of failure. Make sure that the salt is very well mixed by brushing thoroughly at least 5 times. Jandy Zodiac AquaPure PLC1400 PLC 1400 Saltwater Cell Kit AQUA PURE. See wiring diagram in Figures 2a, 2b, and 2c of the owner's manual. (Use sodium chloride only). If there's a little adapter card between the old sensor cord and the circuit board, remove the adapter card. Backwash or partially drain pool and dilute with fresh water until salinity returns to 3.0 gpl to 3.5 gpl. If so, yes it does., Customer Reviews, including Product Star Ratings help customers to learn more about the product and decide whether it is the right product for them.Learn more how customers reviews work on Amazon. Look for heavy corrosion at both ends. Release the button after the 3rd beep. AquaPure Electronic Salt Water Chlorinator & PureLink Water Purification System Power Center & Cell Kit Installation & Operation Manual. What is polarity inversion on a salt water chlorinator? The controller will periodically change the direction of the cell current in order to eliminate the layers of scale that deposit on the electrode plates. Would buy again from them. Free shipping for many products! Press and release the Temperature button within 5 seconds to enter the salinity calibration screen. Q: Jandy's replacement Power Center Transformer works with the AquaLink RS and AquaPure automatic control systems. The 700 cell has half the number of plates as the 1400 cell. This method would require the purchase of 4 unions. Salt level may decrease after a heavy rain, backwashing, refilling, draining or excessive splash out. There was a problem adding this item to Cart. Features It should use the Air temperature sensor. It's always important to test the salinity before adding salt to determine how much salt should be added. If still too low, Super Chlorinate with outside source. So yes, they are reading two different temps. 2023 Leslies Poolmart Inc. Were sorry we missed you; we look forward to assisting you soon. Salt only needs to be added when necessary. Press the Salinity button and hold it until it beeps 3 times. The audible alarm can be permanently disabled by removing the jumper from J2 on the control/power center Power Interface Board (PIB). Asked on 5/16/2017by Steve. You can check the amperage to verify if the cell is generating. High salt concentration above 4.0 gpl may damage the power center. Check that unit is correctly wired for 240 VAC and connected to 240 VAC. Add stabilizer to maintain 50 - 75 PPM per pool professionals recommendations. If removing the cell is desired so that water may circulate without the cell, specialized plumbing would need to be added during installation of the cell. The only hiccup we get, is an occasional communication error. Thank You. Most cases of corrosion can be better explained by an incorrect water chemistry as opposed to the presence of salt. The manual says that the unit can be damaged, which could void the warranty. In fairness to Zodiac/Jandy, they feel that a pool professional should do this. Winterize your pool. Turn the chlorinator off or reduce the chlorine production percentage to zero. It includes aquapure control box only. This issue is with the trisensor, which is a separate part that installs in the cell. Why You Should Only Work With A Qualified Professional. with the pool water. Field switchable to power all PureLink, ClorMatic and Nature2 Fusion Soft cell kits, LCD monitoring of chlorine production, cell modes, salinity, temperature, water flow and diagnostics. Replace the Power Cord When you Replace the Cell, Replacing Old Square Jandy PLC700/1400 Cell, AquaPure Resets to 35% Everytime it is Powered On, AquaPure and PureLink Tri-Sensor Adapter Installation Kit Manual, Jandy AquaPure, PureLink & Nature Fusion Soft Workbook, https://www.troublefreepool.com/threads/need-intelliflo-and-jandy-aquapure-1400-folks.254612/post-2226671, https://www.troublefreepool.com/threads/plc1400-and-r0452400-compatible.260746/#post-2280305, https://www.troublefreepool.com/threads/six-month-old-jandy-plc1400-smoking-melting-rubber-wire-connector.198600/post-1752937, https://www.jandy.com/-/media/zodiac/global/downloads/h/h0325600.pdf, https://www.troublefreepool.com/threads/aquapure-cycle-time-wiki-correction.264622/#post-2321916, http://viewer.zmags.com/publication/1a29b06c#/1a29b06c/892, https://www.troublefreepool.com/threads/when-did-jandy-declare-war-on-diy.176586/post-1558946, https://www.troublefreepool.com/threads/jandy-old-square-salt-cell-replacement.201262/, https://www.troublefreepool.com/threads/jandy-aquapure-1400-error-120.236117/, https://www.troublefreepool.com/threads/aquapure-1400-receiving-error-code-123.46288/post-387518, https://www.troublefreepool.com/threads/jandy-aquapure-plc-700-not-producing-chlorine.220478/post-1929929, https://www.troublefreepool.com/threads/will-a-new-water-temp-sensor-fix-this-aquapure-swg-scenario.243392/, https://www.troublefreepool.com/threads/jandy-pda-wasnt-displaying-aquapure-info.194647/post-1715658, https://www.troublefreepool.com/threads/aquapure-keeps-resetting-to-chlorine-rate-35-from-pool-pump-timer.197670/post-1743853, https://www.troublefreepool.com/threads/jandy-power-center-transformer-replacement-aquapure.194422/, https://www.troublefreepool.com/wiki/index.php?title=Jandy_AquaPure_SWG&oldid=5928, PURE700 - 0.625 lb./24 Hr.